www.industryemea.com
27
'26
Written on Modified on
Fluke unveils its highest-performing acoustic imagers
The Fluke ii1050 and ii1030 acoustic imagers combine advanced detection, thermal imaging, and built-in reporting to quickly identify anomalies and limit unplanned downtime.
www.fluke.com

Industrial facility managers and reliability engineers face rising energy costs, strict uptime targets, and a persistent shortage of experienced maintenance technicians. Invisible compressed air, specialty gas, and vacuum leaks continuously drain plant energy budgets, while incipient partial discharge in high-voltage electrical assets and early-stage mechanical bearing faults can escalate into catastrophic equipment failures and safety incidents. Conventional ultrasonic leak detectors require slow, point-by-point scanning and heavy operator expertise to interpret audio signals, whereas previous-generation acoustic imagers often suffered from bulky form factors that caused operator fatigue during full-shift inspections or restricted access inside tight machinery enclosures. Overcoming these operational hurdles requires lightweight, high-channel-count acoustic cameras paired with integrated thermography and automated on-device reporting to translate complex acoustic signatures into clear, actionable maintenance priorities on the plant floor.
High-Density 202-Microphone Array in a 40 Percent Smaller Form Factor
To accelerate non-invasive fault localization across demanding industrial environments, Fluke unveiled the ii1050 and ii1030 acoustic imagers. Measuring approximately 40 percent smaller than previous-generation models and weighing roughly 1.2 kilograms, the handheld units reduce technician fatigue during extended plant walkdowns and fit easily into cramped switchgear cabinets and congested process piping zones. Despite the reduced chassis footprint, both cameras retain the same full-size display—now upgraded with an anti-glare coating for clear outdoor and high-bay legibility—alongside an IP54-rated ruggedized enclosure built to withstand dust and moisture ingress.
Acoustically, the ii1050 and ii1030 triple sensor density from 64 to 202 microphones, enabling detection of fainter ultrasonic emissions and sharper spatial pinpointing of fault sources from a safe standoff distance. A high-resolution 13-megapixel visible-light camera overlays crisp visual context onto the acoustic SoundMap, supported by an integrated LED flashlight for dark mechanical bays.
Plug-In TC03A Thermal Imaging and On-Device Reporting
To streamline multi-modal condition monitoring, both acoustic imagers integrate compatibility with Fluke’s new TC03A plug-in thermal camera, allowing technicians to combine ultrasonic anomaly detection with infrared temperature context during a single inspection pass. Tako Feron, Senior Product Manager for Acoustic Imaging at Fluke, noted that as experienced maintenance personnel become scarcer, teams require intuitive tools that transform complex diagnostic data into clear on-site insights—helping plants curb energy waste, boost equipment reliability, and prevent costly unplanned downtime.
Equipped with on-device inspection evaluation, prioritization, and automated report generation tools, the ii1050 and ii1030 enable maintenance teams to locate compressed air, gas, and vacuum leaks, detect electrical partial discharge, and identify early mechanical wear before failures occur.

Additional Context
This section details technical specifications and competitive benchmarking not included in the original product announcement.
In industrial ultrasonic acoustic imaging, expanding an array from 64 to 202 digital MEMS microphones significantly improves signal-to-noise ratio (SNR) and beamforming spatial resolution, suppressing background plant noise while resolving low-amplitude leaks and corona/tracking partial discharge across ultrasonic frequency bands (typically 2 kHz to 100 kHz). Pairing acoustic beamforming with plug-in infrared thermography (such as the USB-connected TC03A) allows reliability engineers to cross-verify electrical partial discharge—which ionizes air before generating significant resistive heating—with thermal hot spots on switchgear busbars and transformer bushings under ISO 18434-1 condition monitoring workflows.
Within the handheld industrial acoustic imaging market, Fluke’s ii1050 and ii1030 benchmark directly against Teledyne FLIR’s Si2 series (Si2-LD, Si2-PD, and Si2-Pro, featuring 124 microphones), Crysound’s CRY2624/CRY8124 acoustic imagers, Sorama’s CAM iV64, and UE Systems’ UltraView camera. While FLIR’s Si2 series set a strong benchmark for lightweight ergonomics and partial discharge classification, Fluke’s 202-microphone array, 13 MP optical camera, and modular TC03A thermal integration establish a high-density acoustic-thermal diagnostic platform tailored for rapid plant-wide leak audits and high-voltage electrical inspections.
Edited by Romila DSilva, Induportals Editor, with AI assistance.
www.fluke.com